Sign In | Join Free | My china-telecommunications.com
China China World Technology Medical Equipment Service Group logo
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group Win-win together!
Verified Supplier

5 Years

Home > ECG Machine Parts >

GE MAC 2000 Resting ECG EKG Analysis System For Repair In Hospital

China World Technology Medical Equipment Service Group
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

GE MAC 2000 Resting ECG EKG Analysis System For Repair In Hospital

Brand Name : GE

Model Number : MAC2000

Certification : CE

MOQ : 1pcs

Payment Terms : T/T(wire transfer), Western Union, Paypal

Delivery Time : 3-5 working days

Packaging Details : Carton

Product Name : GE MAC 2000 ECG Analysis System For Repair

Brand : GE

Item No. : Mac2000

Display type : 7 in. color TFT display with support of minimum 32K colors

Display resolution : WVGA resolution – 800 x 480

Display data : Heart rate, patient ID, clock, battery power indicator, waveforms, lead lables, speed, gain and filter settings, warning messages, prompts, help messages, and 12-lead display

Height : 200 mm

Width : 390mm

Weight : Approx. 5 Kg including battery, without paper

ECG Interpretation : Marquette* 12SL ECG Analysis Program for Adults and Pediatrics

Computerized measurements : 12-lead analysis

ECG analysis frequency : 500 or 1000 samples/second/channel

Digital sampling rate : 16000 samples/second/channel for normal data acquisition

Pace sampling rate : 75K samples/second/channel

Contact Now

GE MAC 2000 ECG Analysis System For Repair

MAC 2000 ECG Analysis System

The MAC 2000 ECG Analysis System is a portable ECG acquisition, analysis and recording system designed for use by a trained operator in a hospital or medical professional's facility setting, as well as in a clinic, PHiliphhilipysician's office, outreach center or any ECG for testing.

The MAC™ 2000 Electrocardiogram Analysis System is a portable device designed to acquire, analyze, display and record information on adult and pediatric populations in hospitals, medical Professional facilities, clinics, doctor's offices or outreach centers.

notes:

The pediatric population was defined as patients between the ages of 0 and 15 years.

The MAC™2000 ECG Analysis System offers the following modes of operation:

• Resting ECG mode

This mode is the default mode for your system.

• Arrhythmia patterns

This mode is intended to facilitate the automatic creation of documentation.

You can upgrade the basic system with two additional operating modes:

• Exercise mode for exercise stress test (optional)

This mode is used to test PHiliphhilipysical exertion.

• RR analysis mode for RR interval analysis (optional)

This mode is used for RR interval analysis

The basic system prints 6 or 12 EKG derivatives and optionally offers the transmission and reception of EKG data to a central cardiovascular EKG information system. You can also upgrade with software options such as 12-lead ECG measurement and interpretation analysis.

Contraindications

This system is not suitable for use in the following ways:

• During patient transport

• Equipped with high frequency surgical equipment

• As intracardiac application

• As a vital signs PHiliphhilipysiological monitor

ECG Interpretation Marquette* 12SL ECG Analysis Program for Adults and Pediatrics
Computerized measurements 12-lead analysis
ECG analysis frequency 500 or 1000 samples/second/channel
Digital sampling rate 16000 samples/second/channel for normal data acquisition
Pace sampling rate 75K samples/second/channel
ECG on-screen preview On-screen preview of acquired 10 second ECG waveform
Acquisition mode Provides 10 seconds of instantaneous ECG acquisition
Dynamic range AC Differential ±5 mV, DC offset ±300 mV
Resolution 4.88 µV +/-1% per LSB @ 500 SPS
Frequency range 0.04 to 150 Hz
Low cut off frequency 0.04 Hz (ADS off), 0.56 Hz (ADS On)
High cut off frequency Configurable at 20 Hz, 40 Hz, 100 Hz or 150 Hz
Common mode rejection >135 dB (with 50/60 Hz filter ON)
Input impedance >10MΩ @ 10 Hz
Lead detection All disconnected lead detection except RL & RA
Heart rate meter 30 to 300 BPM
Operating system Microsoft® Windows® CE 6.0
Start-up time Less than 30 seconds
Display type 7 in. color TFT display with support of minimum 32K colors
Display resolution WVGA resolution – 800 x 480
Display data Heart rate, patient ID, clock, battery power indicator, waveforms, lead lables, speed, gain and filter settings, warning messages, prompts, help messages, and 12-lead display
ECG Cables/Leadwires

• IEC/AHA Value 10LD Patient Cable/Leadwire

• 10-lead IEC/AHA Patient trunk cable

• 14-lead IEC/AHA Patient trunk cable

• IEC/AHA (Nst, Nax) Leadwire set (ECG 10-L w/resist, Banana)

• IEC/AHA Set of leadwires (4mm connector, 10 leads, defibrillator proof)

ECG Adapter

IEC/AHA Kit Adapter, 10 set Banana

Electrode Prep Pads, CLIP Universal GE 10/Pkg

Electrodes

• ECG Electrode Clamp (Large, 4/set)

• Baby MAC electrodes

• Silver Mactrode Plus 1000/CASE

• Electrode Application System KISS 10-lead without pump

• Electrode Application System KISS 12-lead without pump

Height 200 mm
Width 390mm
Depth 330mm
Weight Approx. 5 Kg including battery, without paper


Product Tags:

ECG EKG Analysis System

      

GE MAC 2000 Analysis System

      
Quality GE MAC 2000 Resting ECG EKG Analysis System For Repair In Hospital for sale

GE MAC 2000 Resting ECG EKG Analysis System For Repair In Hospital Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: China World Technology Medical Equipment Service Group
*Subject:
*Message:
Characters Remaining: (0/3000)